The 711 Impulse Sequencing relay is a latching relay used for load sharing or toggling ON/OFF of the load.

Uni-directional momentary pulses cause the contacts to transfer from one side to the other (i.e. "flip-flop"). There is no need to redirect the polarity of the input in order to change and maintain states.711XBX
Unit of Measure

Specifications

Check Inventory

N/A Check Distributor Inventory

Status

N/A Obsolete

Contact Characteristics

Contact Configuration

N/A 4PDT

Contact Rating (switching current max)

N/A 15 A

Contact Materials

N/A Silver Alloy

Maximum Switching Voltage (V)

N/A 600 V

Switching Current at Voltage (Resistive)

N/A 10 A at 28 VDC 15 A at 240 VAC 50/60 Hz

Minimum Switching Requirement

N/A 100 mA at 5 VDC (0.5W)

Coil Characteristics

Coil Voltage

N/A 120 VAC 50/60 Hz

Control

N/A AC

Coil Resistance (Ohms)

N/A 3800 Ohm

Control Type

N/A Single Coil

Drop-out Voltage Threshold

N/A 10% DC 15% AC

Operating Range

N/A 80 to 110% DC 85 to 110% AC

Average Consumption

N/A 1.64 W 2 VA

Miscellaneous

Pin Orientation

N/A Blade

Weight

N/A 85 grams

Performance Characteristics

Electrical Life (Resistive)

N/A 100000 Operations at Rated Current

Mechanical Life

N/A 10000000 Unpowered Operations

Operating Time (Response Time)

N/A 25 ms

Dielectric Strength

N/A 1500 VAC (rms) Between contacts 1500 VAC (rms) Between poles 2000 VAC (rms) Between coil & contact

Environment

Ambient air temperature around the device

N/A -40 to +55_ C (Operation) -40_ to 85_ C (Storage)

Vibration Resistance (Operational)

N/A 3 g-n at 10-55 Hz

Shock Resistance

N/A 10 g-n

Degree of Protection

N/A IP 40

Product Certifications

Agency Approvals

N/A UR RoHS